Sizing · Last checked November 25, 2026

800W vs 1200W Balcony Solar: How Many Panels per Microinverter?

Use the microinverter's continuous AC watts, then its number of panel inputs. 800 W AC is about 6.7 amps at 120 volts. 1,200 W AC is 10 amps. Most laws in our file stop at 1,200 W. A dual-input inverter takes two panels. It does not take four, and a second inverter on the same outlet is not how you "use the rest of the cap."

Ready to buy? See top kits for this setup →

Savings estimate

800 W and 1,200 W are not the same year

This run is 800 W, south-facing, vertical, Los Angeles: about 795 kWh a year in PVWatts v8. Press 1,200 W to scale the same roof. Production is not the legal cap, and it is not the inverter's input count.

System size

California · reference city Los Angeles · vertical, south

794 kWh/yr

About $172 a year at 30.86¢/kWh, counting 70% used at home.

  • Reference climate: Los Angeles. The ZIP code selects the state only. Shade, railing height, and the building across the street are not in this number.
  • Electricity price: 30.86¢ per kWh, EIA residential average for September 2026, released 2026-11-24. Your tariff can differ.
  • Plug-in laws in this file do not pay for exported energy. Dollar savings count only the share you use while the panels are producing.
  • Mount: vertical railing, 90° tilt, fixed open rack, standard module, 14% losses, DC-to-AC ratio 1.0.
  • This state's reference yields are from NREL PVWatts v8. A server-side PVWatts proxy can replace the table later with your exact location. No API key is in this page.
  • California's law is signed and takes effect January 1, 2027. It is not in force yet.

Full method, sources, and the PVWatts proxy note are on the calculator page.

Kits for this problem

Inverters and panels, sized under the cap

Renogy sells panels, charge controllers, and microinverters. Match the inverter's AC rating to the cap before you match the panel count. Vevor is budget panels, mounts, and cables. BLUETTI is the no-backfeed alternative when you want panel watts stored in a station instead of pushed through a plug.

Solar panels, charge controllers, and microinverters

Renogy

Parts for a small array: panels, charge controllers, and microinverters. A microinverter that plugs into an outlet still has to be listed for that use and allowed by your state and your utility. Buying the parts is not permission to connect them.

View Renogy offer

Budget panels, mounts, and cables

Vevor

Lower-cost panels, mounts, and cables for a small array. Check the listing, the connectors, and whether a mount is actually rated for a railing and for wind. Budget hardware still has to stay inside any state watt cap and listing rule.

View Vevor offer

Portable power stations and solar panels sold for the US market

BLUETTI

Treat the US listing as a solar-charged power station. A balcony inverter built for another country's voltage or plug is a different product. Read the model spec before you buy, and do not assume it may backfeed a US outlet.

View BLUETTI offer

Advertising disclosure: a live partner link may earn this site a commission. You do not pay extra. Rates are not shown. No prices, ratings, or reviews are printed here. Affiliate disclosure.

The pain: four panels and one plug

The shopping page says 800 W or 1,200 W. The carton has two panels, or four. The microinverter is a small box with one cord. People add the panel stickers, get 1,600 W, and think they bought a 1,600 W legal system. The statute, where we have one, is counting what the inverter sends into the outlet.

AC cap versus panel stickers

Our law file uses these ceilings: 1,200 W in Utah, Maryland, Vermont, Connecticut, California, New Hampshire, Virginia, New Jersey, and the pending New York bill; 1,920 W in Colorado; and, in Maine's summaries, 420 W if you install it yourself, up to 1,200 W with a licensed electrician. Those numbers are device output. The Clean Energy States Alliance brief describes the same split: panels are DC, the cap is AC, and an inverter fed with extra DC watts clips rather than becoming a larger legal system.

Clipping means a bright hour is flattened at the inverter's AC rating. Two 500 W panels on an 800 W inverter can add up to 1,000 W of DC nameplate and still only deliver 800 W AC when both are in full sun. You did not cheat the cap. You also did not get 1,000 W into the house.

How many panels per microinverter

Read two lines on the inverter label. The first is maximum continuous AC output. The second is how many DC inputs it has, and the module watts, voltage, and current each input allows.

  • One input: one panel, and that panel has to sit inside the voltage window. The AC rating might be 300 to 500 W. Several of those on one circuit add up. Stop at the state cap and at the breaker.
  • Two inputs: two panels. This is the usual balcony shape. Each input tracks its own panel. The AC output is still one number for the whole box.
  • More panels than inputs: not by splicing two modules onto one input unless the manufacturer lists that pair. Parallel strings are a design, not a balcony shortcut.

A published example is the APsystems EZ1-LV. The maker's consumer page says it connects one or two panels, with AC output up to 900 W, and a recommended module range of about 315 W to 660 W per input. This site does not sell that inverter. The example is here so the ratio is concrete: two panels, 900 W AC, which sits under a 1,200 W statutory cap and does not equal 660 + 660 of legal output.

800 W of AC output wants an inverter rated at 800 W, or an inverter rated higher that you are not allowed to run higher because of the cap. 1,200 W of AC output wants an inverter whose continuous rating is 1,200 W or less if 1,200 W is the legal ceiling. An inverter rated 1,500 W does not become legal because you "only bought 1,200 W of panels." If it can send 1,500 W, the cap conversation is about the inverter.

800 W versus 1,200 W in the house

At 120 volts, 800 W is about 6.7 amps and 1,200 W is 10 amps. A 15-amp breaker used continuously is often held to 12 amps, about 1,440 W. Both sizes fit that arithmetic. They do not fit the same daytime load. If the home only draws 400 W at noon, an 1,200 W inverter exports the rest. Our file's laws do not pay for that export. The extra energy problem is on the export page.

On the Los Angeles vertical south-facing check, 800 W is about 794 kWh a year. The 1,200 W button on the calculator scales the same weather. Shade, an east railing, and a vertical mount move the result more than the argument between 800 and 1,200. Maine's 420 W self-install line, where the summaries describe it, is a third size. Do not buy the 1,200 W inverter and call 420 W of it a self-install.

What to do, in order

  1. Look up the cap for your state on the state map. If there is no exemption, a backfeeding inverter is still an interconnection question. California's 1,200 W cap starts January 1, 2027, not today.
  2. Pick the inverter AC rating first. It has to be at or under the cap, and at or under what the circuit can take. See breaker masking before you pick the outlet.
  3. Count inputs. Buy that many panels, inside the module range printed for each input. Two inputs, two panels. One input, one panel.
  4. Do not add a second plug-in inverter to "fill" the cap on the same circuit. The currents add. The breaker may not see the sum.
  5. If you want more panel area than the cap allows into the wall, the rest of the panels belong on a station or a charge controller, not on a second backfeed. That is a different product, with its own label.

Last checked November 25, 2026. Hardware listings change. Read the label on the unit you buy.

Questions people ask next

Is 800W or 1,200W the panel rating?

In the state laws in our file, the cap is the power the device sends into the building. That is AC output from the inverter. Panel ratings are DC nameplate watts. An inverter can be connected to more DC watts than its AC rating. It simply will not send out more than its AC rating on a bright hour.

How many panels can one microinverter take?

As many as it has inputs, and only modules inside the voltage and current window on its label. A dual-input balcony inverter takes two panels. A single-input microinverter takes one. You do not land four panels on two inputs by paralleling them yourself unless the label says that exact combination is allowed.

Can I put two 800W inverters on one outlet to reach 1,200W?

No. Two inverters add their AC current on the same circuit. 800 plus 800 is already past a 1,200 W cap and past the continuous load of a typical 15-amp breaker. One plug-in device per circuit.

What is a real example of two panels on one inverter?

APsystems publishes the EZ1-LV as a balcony microinverter with two inputs and 900 VA maximum continuous AC output. The recommended module range on the maker's page is about 315 W to 660 W per input. That is one manufacturer's spec, not a kit this site sells, and the AC output is 900 W, not 1,200 W. Use it as the shape of the math: two panels, one AC cap.

Does Colorado's 1,920 W cap change the panel count?

It changes the legal AC ceiling in our file, not the inverter's input count. You still cannot exceed what that inverter is listed to do. 1,920 W is about 16 amps at 120 volts, which is a different circuit conversation than 10 amps. Read the Colorado page and the breaker-panel page before you size to the higher cap.